Abstract

A standardized procedure for label-free nano-LC-SRM analysis of 32 high-medium abundance proteins from nondepleted human plasma was established and SRM data were acquired on 45 separate days for a control sample that was independently prepared on 39 distinct dates over an 18-month period (542 days). This case study enabled us to assess quantitative variance associated with nano-LC-SRM plasma analysis, mimicking experimental conditions that would be experienced with clinical trial biomarker studies. We assessed sample preparation variability attributed to different technicians and sample storage stability. Instrument performance varied over the 18-month period requiring ion path cleaning, so we assessed the impact of declining performance on specific peptide ion sensitivity and evaluated how various data normalization strategies could compensate for these changes. Our analysis demonstrated that while sample preparation was the main contributor for data variances when MS data were acquired within days, variability in SRM sensitivity was a far greater source of variance when data were acquired over a long period. The overall median multiplexed assay CV was 13% over the 18-month period. This case study is illustrative of large-scale plasma biomarker studies using nano-LC-SRM over extended periods and highlights aspects of bioanalysis that require careful attention to ensure reliable quantitation.

LanguageEnglish
Pages2118-2127
Number of pages10
JournalProteomics
Volume16
Issue number15-16
DOIs
Publication statusPublished - 1 Aug 2016

Fingerprint

Plasma (human)
Biomarkers
Ions
Plasmas
Labels
Cleaning
Assays
Peptides
Clinical Trials
Proteins

Keywords

  • biomarker
  • mass spectrometry
  • plasma
  • quantitation
  • selected reaction monitoring
  • technology

Cite this

@article{56319494c6f742bbb31639463c425280,
title = "Analytical performance of nano-LC-SRM using nondepleted human plasma over an 18-month period",
abstract = "A standardized procedure for label-free nano-LC-SRM analysis of 32 high-medium abundance proteins from nondepleted human plasma was established and SRM data were acquired on 45 separate days for a control sample that was independently prepared on 39 distinct dates over an 18-month period (542 days). This case study enabled us to assess quantitative variance associated with nano-LC-SRM plasma analysis, mimicking experimental conditions that would be experienced with clinical trial biomarker studies. We assessed sample preparation variability attributed to different technicians and sample storage stability. Instrument performance varied over the 18-month period requiring ion path cleaning, so we assessed the impact of declining performance on specific peptide ion sensitivity and evaluated how various data normalization strategies could compensate for these changes. Our analysis demonstrated that while sample preparation was the main contributor for data variances when MS data were acquired within days, variability in SRM sensitivity was a far greater source of variance when data were acquired over a long period. The overall median multiplexed assay CV was 13{\%} over the 18-month period. This case study is illustrative of large-scale plasma biomarker studies using nano-LC-SRM over extended periods and highlights aspects of bioanalysis that require careful attention to ensure reliable quantitation.",
keywords = "biomarker, mass spectrometry, plasma, quantitation, selected reaction monitoring, technology",
author = "Xiaomin Song and Ardeshir Amirkhani and Wu, {Jemma X.} and Dana Pascovici and Thiri Zaw and Dylan Xavier and Clarke, {Stephen J.} and Molloy, {Mark P.}",
year = "2016",
month = "8",
day = "1",
doi = "10.1002/pmic.201500507",
language = "English",
volume = "16",
pages = "2118--2127",
journal = "Proteomics",
issn = "1615-9853",
publisher = "Wiley-Liss, Wiley",
number = "15-16",

}

Analytical performance of nano-LC-SRM using nondepleted human plasma over an 18-month period. / Song, Xiaomin; Amirkhani, Ardeshir; Wu, Jemma X.; Pascovici, Dana; Zaw, Thiri; Xavier, Dylan; Clarke, Stephen J.; Molloy, Mark P.

In: Proteomics, Vol. 16, No. 15-16, 01.08.2016, p. 2118-2127.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Analytical performance of nano-LC-SRM using nondepleted human plasma over an 18-month period

AU - Song, Xiaomin

AU - Amirkhani, Ardeshir

AU - Wu, Jemma X.

AU - Pascovici, Dana

AU - Zaw, Thiri

AU - Xavier, Dylan

AU - Clarke, Stephen J.

AU - Molloy, Mark P.

PY - 2016/8/1

Y1 - 2016/8/1

N2 - A standardized procedure for label-free nano-LC-SRM analysis of 32 high-medium abundance proteins from nondepleted human plasma was established and SRM data were acquired on 45 separate days for a control sample that was independently prepared on 39 distinct dates over an 18-month period (542 days). This case study enabled us to assess quantitative variance associated with nano-LC-SRM plasma analysis, mimicking experimental conditions that would be experienced with clinical trial biomarker studies. We assessed sample preparation variability attributed to different technicians and sample storage stability. Instrument performance varied over the 18-month period requiring ion path cleaning, so we assessed the impact of declining performance on specific peptide ion sensitivity and evaluated how various data normalization strategies could compensate for these changes. Our analysis demonstrated that while sample preparation was the main contributor for data variances when MS data were acquired within days, variability in SRM sensitivity was a far greater source of variance when data were acquired over a long period. The overall median multiplexed assay CV was 13% over the 18-month period. This case study is illustrative of large-scale plasma biomarker studies using nano-LC-SRM over extended periods and highlights aspects of bioanalysis that require careful attention to ensure reliable quantitation.

AB - A standardized procedure for label-free nano-LC-SRM analysis of 32 high-medium abundance proteins from nondepleted human plasma was established and SRM data were acquired on 45 separate days for a control sample that was independently prepared on 39 distinct dates over an 18-month period (542 days). This case study enabled us to assess quantitative variance associated with nano-LC-SRM plasma analysis, mimicking experimental conditions that would be experienced with clinical trial biomarker studies. We assessed sample preparation variability attributed to different technicians and sample storage stability. Instrument performance varied over the 18-month period requiring ion path cleaning, so we assessed the impact of declining performance on specific peptide ion sensitivity and evaluated how various data normalization strategies could compensate for these changes. Our analysis demonstrated that while sample preparation was the main contributor for data variances when MS data were acquired within days, variability in SRM sensitivity was a far greater source of variance when data were acquired over a long period. The overall median multiplexed assay CV was 13% over the 18-month period. This case study is illustrative of large-scale plasma biomarker studies using nano-LC-SRM over extended periods and highlights aspects of bioanalysis that require careful attention to ensure reliable quantitation.

KW - biomarker

KW - mass spectrometry

KW - plasma

KW - quantitation

KW - selected reaction monitoring

KW - technology

UR - http://www.scopus.com/inward/record.url?scp=84983356150&partnerID=8YFLogxK

U2 - 10.1002/pmic.201500507

DO - 10.1002/pmic.201500507

M3 - Article

VL - 16

SP - 2118

EP - 2127

JO - Proteomics

T2 - Proteomics

JF - Proteomics

SN - 1615-9853

IS - 15-16

ER -