T1 - Anteroposterior versus anterolateral electrode position for direct current cardioversion of atrial fibrillation
T2 - a meta-analysis of randomised controlled trials
AU - Virk, Sohaib A.
AU - Rubenis, Imants
AU - Brieger, David
AU - Raju, Hariharan
PY - 2022/12
Y1 - 2022/12
N2 - Objective: Data regarding optimal electrode positioning for direct current cardioversion (DCCV) of atrial fibrillation (AF) has been inconsistent. This meta-analysis was conducted to systematically compare the efficacy of anteroposterior (AP) versus anterolateral (AL) electrode placement for DCCV of AF. Methods: Electronic databases were searched for randomised controlled trials (RCTs) comparing AP versus AL electrode positioning in patients undergoing DCCV for AF. Primary endpoints were first-shock success and overall DCCV success. Subgroup analysis was performed by defibrillator waveform (monophasic versus biphasic). Meta-regression analyses were performed to assess for significant moderators. Results: Twelve (12) RCTs, including a total of 2,046 patients, met inclusion criteria. Neither first-shock success (relative risk [RR] 0.92; 95% CI 0.79–1.07; p=0.28) nor overall DCCV success (RR 1.01; 95% CI 0.96–1.05; p=0.78) were significantly different with AP versus AL electrode positioning. The mean number of shocks (mean difference [MD] 0.3, 95% CI -0.4 to 0.9), energy level of first successful shock (MD 3 joules; 95% CI -20 to 27) and cumulative energy delivered (MD 39 joules; 95% CI -168 to 246) were similar in AP versus AL arms. In subgroup analysis of six RCTs using biphasic defibrillators, improvement in first-shock success (RR 0.85; 95% CI 0.69–1.03; p=0.10) and overall DCCV success (RR 0.97; 95% CI 0.93–1.01; p=0.09) with AL electrode positioning did not reach statistical significance. Meta-regression analyses identified older age, higher body mass index, and longer AF duration as significant moderators favouring AL electrode positioning. Conclusions: Pooled analysis of randomised data overall does not show a significant difference in efficacy between AP versus AL electrode positioning. Meta-regression and subgroup analyses suggest that, in contemporary practice with use of biphasic defibrillators, there may be a subset of AF patients in whom AL electrode positioning improves efficacy of DCCV.
AB - Objective: Data regarding optimal electrode positioning for direct current cardioversion (DCCV) of atrial fibrillation (AF) has been inconsistent. This meta-analysis was conducted to systematically compare the efficacy of anteroposterior (AP) versus anterolateral (AL) electrode placement for DCCV of AF. Methods: Electronic databases were searched for randomised controlled trials (RCTs) comparing AP versus AL electrode positioning in patients undergoing DCCV for AF. Primary endpoints were first-shock success and overall DCCV success. Subgroup analysis was performed by defibrillator waveform (monophasic versus biphasic). Meta-regression analyses were performed to assess for significant moderators. Results: Twelve (12) RCTs, including a total of 2,046 patients, met inclusion criteria. Neither first-shock success (relative risk [RR] 0.92; 95% CI 0.79–1.07; p=0.28) nor overall DCCV success (RR 1.01; 95% CI 0.96–1.05; p=0.78) were significantly different with AP versus AL electrode positioning. The mean number of shocks (mean difference [MD] 0.3, 95% CI -0.4 to 0.9), energy level of first successful shock (MD 3 joules; 95% CI -20 to 27) and cumulative energy delivered (MD 39 joules; 95% CI -168 to 246) were similar in AP versus AL arms. In subgroup analysis of six RCTs using biphasic defibrillators, improvement in first-shock success (RR 0.85; 95% CI 0.69–1.03; p=0.10) and overall DCCV success (RR 0.97; 95% CI 0.93–1.01; p=0.09) with AL electrode positioning did not reach statistical significance. Meta-regression analyses identified older age, higher body mass index, and longer AF duration as significant moderators favouring AL electrode positioning. Conclusions: Pooled analysis of randomised data overall does not show a significant difference in efficacy between AP versus AL electrode positioning. Meta-regression and subgroup analyses suggest that, in contemporary practice with use of biphasic defibrillators, there may be a subset of AF patients in whom AL electrode positioning improves efficacy of DCCV.
KW - Atrial fibrillation
KW - Direct current cardioversion
KW - Electrode position
KW - Meta-analysis
UR - http://www.scopus.com/inward/record.url?scp=85138818229&partnerID=8YFLogxK
U2 - 10.1016/j.hlc.2022.08.016
DO - 10.1016/j.hlc.2022.08.016
M3 - Article
C2 - 36163316
AN - SCOPUS:85138818229
SN - 1443-9506
VL - 31
SP - 1640
EP - 1648
JO - Heart Lung and Circulation
JF - Heart Lung and Circulation
IS - 12
ER -