Abstract
Background: In anterior cruciate ligament reconstruction, quadrupled semitendinosus (Quad ST) grafts have potential advantages over doubled semitendinosus–gracilis (ST/G) including larger diameter and gracilis preservation, however the ideal tibial fixation method of the resultant shorter Quad ST graft remains elusive if a fixed-loop suspensory fixation device is used on the femur. We investigated whether the tibial fixation biomechanical properties of a Quad ST fixed indirectly with polyethylene terephthalate tape tied over a screw in a full outside-in created tunnel was superior to a ST/G graft fixed with an interference screw. Materials and methods: In a controlled laboratory study, six cadaveric matched pairs of each construct were subjected to cyclic loading to mimic physiologic loading during rehabilitation. This included preconditioning cycling, cyclic loading to 220 N for 500 cycles, then cyclic loading to 500 N for 500 cycles. Results: High standard deviations across the measured parameters occurred with no significant difference between measured parameters of elongation for the different constructs. Elongation of the Quad-ST construct was greater at 10 and 100 cycles, but not statistically different. Four of the six Quad-ST constructs failed below 100 cycles, compared with two failures below 100 cycles in the ST/G construct. There was a strong correlation between cycles to failure and bone mineral density for the Quad ST-tape constructs. Conclusions: Tibial fixation of Quad ST with a tied tape–screw construct in a full-length tunnel was not biomechanically superior to ST/G graft fixed with an interference screw, exhibited greater nonsignificant construct elongation with earlier failure, and was more reliant on bone mineral density. Level of evidence: In vitro laboratory study.
Original language | English |
---|---|
Article number | 11 |
Pages (from-to) | 1-11 |
Number of pages | 11 |
Journal | Journal of Orthopaedics and Traumatology |
Volume | 19 |
Issue number | 1 |
DOIs | |
Publication status | Published - 1 Dec 2018 |
Bibliographical note
Copyright the Author(s) 2018. Version archived for private and non-commercial use with the permission of the author/s and according to publisher conditions. For further rights please contact the publisher.Keywords
- Anterior cruciate ligament reconstruction
- Biomechanical testing
- Quadrupled semitendinosus graft