TY - JOUR
T1 - Comparative effects of CPAP and mandibular advancement splint therapy on blood pressure variability in moderate to severe obstructive sleep apnoea
AU - Dissanayake, Hasthi U.
AU - Sutherland, Kate
AU - Phillips, Craig L.
AU - Grunstein, Ronald R.
AU - Mihailidou, Anastasia S.
AU - Cistulli, Peter A.
PY - 2021/4
Y1 - 2021/4
N2 - Background: Obstructive sleep apnoea (OSA) is associated with increased blood pressure variability (BPV) and are risk factors for cardiovascular disease. We aimed to assess the comparative effects of two OSA therapies, continuous positive airway pressure (CPAP) and mandibular advancement splint (MAS), on BPV. Methods: This is a secondary analysis of data collected as part of a previously published randomised crossover trial of one month each of CPAP and MAS therapy. BPV was determined from 24-h-ambulatory blood pressure recordings in 92 patients with moderate to severe OSA at baseline and after one month of optimised treatment with each modality. BPV was assessed by three measures: Standard deviation of the mean (SD), Coefficient of variation (CoV), and the Average Real Variability (ARV) index. Results: Neither CPAP nor MAS therapy improved BPV, with no difference between treatments. BPV did not change in hypertensive OSA patients, however, there was a reduction in ARV of diastolic blood pressure in the effectively treated compared to ineffectively treated CPAP patients, Δ ARV 24-h-DBP (mmHg), −0.72 ± 2.14, 0.34 ± 1.52, P = 0.02, respectively. There was no difference between effective versus ineffective MAS treatment, Δ ARV 24-h-DBP (mmHg), −0.04 ± 2.4, 0.02 ± 1.9, P = 1.00, respectively. Conclusions: One month of optimised CPAP or MAS therapy did not improve short term BPV in patients with moderate to severe OSA. The subgroup of patients on effective CPAP showed some improvement in BPV with CPAP but not MAS. Further work on the effect of OSA therapy on BPV following long-term therapy is needed.
AB - Background: Obstructive sleep apnoea (OSA) is associated with increased blood pressure variability (BPV) and are risk factors for cardiovascular disease. We aimed to assess the comparative effects of two OSA therapies, continuous positive airway pressure (CPAP) and mandibular advancement splint (MAS), on BPV. Methods: This is a secondary analysis of data collected as part of a previously published randomised crossover trial of one month each of CPAP and MAS therapy. BPV was determined from 24-h-ambulatory blood pressure recordings in 92 patients with moderate to severe OSA at baseline and after one month of optimised treatment with each modality. BPV was assessed by three measures: Standard deviation of the mean (SD), Coefficient of variation (CoV), and the Average Real Variability (ARV) index. Results: Neither CPAP nor MAS therapy improved BPV, with no difference between treatments. BPV did not change in hypertensive OSA patients, however, there was a reduction in ARV of diastolic blood pressure in the effectively treated compared to ineffectively treated CPAP patients, Δ ARV 24-h-DBP (mmHg), −0.72 ± 2.14, 0.34 ± 1.52, P = 0.02, respectively. There was no difference between effective versus ineffective MAS treatment, Δ ARV 24-h-DBP (mmHg), −0.04 ± 2.4, 0.02 ± 1.9, P = 1.00, respectively. Conclusions: One month of optimised CPAP or MAS therapy did not improve short term BPV in patients with moderate to severe OSA. The subgroup of patients on effective CPAP showed some improvement in BPV with CPAP but not MAS. Further work on the effect of OSA therapy on BPV following long-term therapy is needed.
KW - Blood pressure variability
KW - Continuous positive airway pressure
KW - Mandibular advancement splint
KW - Obstructive sleep apnoea
UR - http://www.scopus.com/inward/record.url?scp=85100897368&partnerID=8YFLogxK
U2 - 10.1016/j.sleep.2021.01.059
DO - 10.1016/j.sleep.2021.01.059
M3 - Article
C2 - 33610954
AN - SCOPUS:85100897368
SN - 1389-9457
VL - 80
SP - 294
EP - 300
JO - Sleep Medicine
JF - Sleep Medicine
ER -