Skip to main navigation Skip to search Skip to main content

Conducting polymer Tri-layer electrodes for low drift potassium and calcium sensing in inner ear applications

Research output: Contribution to journal › Article › peer-review

3 Downloads (Pure)

Abstract

Solid-contact ion-selective electrodes (SC-ISEs) suffer from potential drift that limits their application in long-term biomedical monitoring. We report K⁺ and Ca²⁺ SC-ISEs featuring a novel PEDOT:PSS/polydopamine (PDA)/PEDOT:PSS Tri-layer solid-contact architecture that reduces potential drift through enhanced electrochemical performance. The PDA interlayer, deposited via self-polymerization between two electropolymerized PEDOT:PSS layers, is proposed to facilitate interfacial integration while the Tri-layer architecture provides increased charge-storage capability and reduced interfacial resistance. Cyclic voltammetry, electrochemical impedance spectroscopy, and chronopotentiometry confirmed enhanced capacitance and improved charge-transfer characteristics of the optimized solid contact. The K⁺ and Ca²⁺ sensors exhibited near-Nernstian responses (51.27 ± 1.42 and 24.84 ± 1.34 mV/decade, respectively) with detection limits of 1.0 × 10⁻⁶ and 1.0 × 10⁻⁶⋅² M, respectively. Critically, the Tri-layer design achieved 11-fold and 6-fold reductions in potential drift compared with bare electrodes for K⁺ (0.360 ± 0.01 mV/h) and Ca²⁺ (0.610 ± 0.05 mV/h), respectively, over 20 h. When tested in artificial perilymph and endolymph, the sensors demonstrated stable ion detection over a wide concentration range, across pH 4–8 and temperatures of 25–45 °C, together with excellent selectivity toward interfering ions. This robust, low-drift sensing platform shows promise for continuous ion monitoring in inner-ear research and other biomedical applications.

Original languageEnglish
Article number149976
Pages (from-to)1-15
Number of pages15
JournalElectrochimica Acta
Volume580
DOIs
Publication statusPublished - 20 Dec 2026

Bibliographical note

Copyright the Author(s) 2026. Version archived for private and non-commercial use with the permission of the author/s and according to publisher conditions. For further rights please contact the publisher.

Keywords

  • Ion-selective electrodes
  • PEDOT:PSS
  • Polydopamine
  • Potential drift
  • Inner ear ion monitoring

Fingerprint

Dive into the research topics of 'Conducting polymer Tri-layer electrodes for low drift potassium and calcium sensing in inner ear applications'. Together they form a unique fingerprint.

Cite this