Depth-resolved water temperature measurements using Raman LiDAR

D. J. Spence*, O. Kitzler, C. J. Taylor, S. A. Curtis, B. R. Neimann, J. M. Dawes, J. E. Downes, H. M. Pask

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

We present the retrieval of depth-resolved temperature measurements in water using Raman LiDAR. Using a 5 m pipe of laboratory water, we recover non-homogeneous temperature profiles with a temperature accuracy ranging between 0.35°C and 0.85°C, and a position resolution of 28 cm.

Original languageEnglish
Pages (from-to)4366-4371
Number of pages6
JournalApplied Optics
Volume63
Issue number16
DOIs
Publication statusPublished - 1 Jun 2024

Fingerprint

Dive into the research topics of 'Depth-resolved water temperature measurements using Raman LiDAR'. Together they form a unique fingerprint.