Skip to main navigation Skip to search Skip to main content

Determination of long-range resistance from high resolution impedance spectroscopy in human cadaveric heads

  • Mit B. Bhavsar*
  • , Merle Sehlmeyer
  • , Nils Prenzler
  • , Andrej Kral
  • , Stefan Zimmermann
  • , Hannes Maier
  • *Corresponding author for this work

Research output: Contribution to journal › Article › peer-review

Abstract

Long-range resistance (R t) reflects the resistive component of current flow through intracochlear fluids, surrounding tissues, and bone before it returns to the extracochlear return electrode (RE). Unlike near-field resistances, which mainly capture the local tissue-electrode interface, R t captures the global tissue pathway and therefore represents how efficiently stimulation current spreads throughout the cochlea and surrounding anatomical structures. In this study, we have determined the long-range resistance (R t) between a stimulation electrode (SE) and the extracochlear RE from precision impedance spectroscopic measurements in three human cadaveric heads involving six sequentially cochlear implanted ears with the MED-EL FLEX28 and the Cochlear Ltd. CI622 electrode arrays. Equivalent electrical circuit (EEC) modelling, combined with finite element method (FEM)-based correction, was employed to separate the biological impedance components from non-biological artefacts arising from the measurement setup. Principal Component Analysis (PCA) was applied to detect and remove atypical impedance responses due to malfunctioning electrodes. Missing electrode values were interpolated using cubic splines to maintain continuity. Across both array types, R t consistently increased from basal to apical electrode positions, consistent with the progressively smaller scala tympani cross-section in the apical turn. The overall trend of R t observed in the present study also aligns with trends reported in in vivo telemetry studies, supporting the translational relevance of the measurements.

Original languageEnglish
Number of pages10
JournalZeitschrift fur Medizinische Physik
DOIs
Publication statusE-pub ahead of print - 1 Jul 2026
Externally publishedYes

Keywords

  • cochlear implant
  • long range resistance
  • electrical equivalent circuit
  • modelling
  • impedance spectroscopy

Fingerprint

Dive into the research topics of 'Determination of long-range resistance from high resolution impedance spectroscopy in human cadaveric heads'. Together they form a unique fingerprint.

Cite this