Abstract
Vector magnetometers may be used to determine the in situ magnetic properties of magnetic anomaly sources. The adaptation of caesium-vapour magnetometers to vector measurements has been challenging but rewarding. We describe the considerations that we have taken into account and summarise our success to date.
Original language | English |
---|---|
Pages (from-to) | 123-126 |
Number of pages | 4 |
Journal | Exploration Geophysics |
Volume | 24 |
Issue number | 2 |
DOIs | |
Publication status | Published - 1993 |
Keywords
- Differential
- Diurnal
- In situ Q
- Magnetometer
- Pulsation
- Vector