Skip to main navigation Skip to search Skip to main content

Diagnostic accuracy of noninvasive biomarkers and imaging for evaluating postoperative recurrence in Crohn's disease

  • Sunil Samnani
  • , Christina M. Ray
  • , Priyanka Gill
  • , Levi Stein
  • , Katherine A. Buhler
  • , Rupert W. Leong
  • , Rebecca L. Smith
  • , Peter De Cruz
  • , Gilaad G. Kaplan
  • , Cynthia H. Seow
  • , Cathy Lu
  • , Leonardo Guizzetti
  • , Frank Hoentjen
  • , John K. Marshall
  • , Siddharth Singh
  • , Remo Panaccione
  • , Kerri L. Novak
  • , Christopher Ma*
  • *Corresponding author for this work

Research output: Contribution to journal › Review article › peer-review

3 Downloads (Pure)

Abstract

Background & Aims Colonoscopy is recommended to monitor for Crohn’s disease (CD) recurrence after surgical resection. However, repeated colonoscopy is invasive and resource-intensive. We conducted a systematic review and meta-analysis to evaluate the pooled diagnostic accuracy of noninvasive biomarkers and imaging measures for detecting endoscopic CD recurrence, as compared with colonoscopy. Methods A systematic review was conducted to January 31, 2024, to identify studies evaluating the diagnostic accuracy of C-reactive protein (CRP), fecal calprotectin, computed tomography and magnetic resonance enterography, or intestinal ultrasound (IUS) compared with colonoscopy for detecting CD recurrence. Estimates of sensitivity, specificity, and positive and negative likelihood ratios were pooled using a random-effects hierarchical summary receiver operating characteristic model. Results A total of 17 studies (N = 1080) evaluated inflammatory biomarkers and 20 studies (N = 1053) assessed imaging measures. The pooled sensitivity and specificity of CRP (threshold, 5.0 mg/L) were 0.45 (95% confidence interval [CI], 0.33–0.58) and 0.83 (95% CI, 0.68–0.92), respectively. Fecal calprotectin (threshold, 50 μg/g) was moderately sensitive 0.76 (95% CI, 0.70–0.82) but less specific 0.66 (95% CI, 0.56–0.75). Sensitivity for computed tomography enterography/magnetic resonance enterography and IUS was 0.89 (95% CI, 0.73–0.96) and 0.92 (95% CI, 0.75–0.96); specificity was 0.65 (95% CI, 0.43–0.82) and 0.76 (95% CI, 0.52–0.90), respectively. Using optimized radiographic parameters for IUS, specificity was improved to 0.85 (95% CI, 0.71–0.93). Conclusions The high sensitivity of fecal calprotectin (<50 μg/g) and cross-sectional imaging can help reduce the need for invasive and costly colonoscopy monitoring for CD recurrence after surgery. Applying optimal definitions of sonographic recurrence by IUS parameters may further improve specificity for making therapeutic decisions without endoscopy.

Original languageEnglish
Pages (from-to)2433-2447.e9
Number of pages24
JournalClinical Gastroenterology and Hepatology
Volume23
Issue number13
DOIs
Publication statusPublished - Dec 2025
Externally publishedYes

Bibliographical note

Copyright the Author(s) 2025. Version archived for private and non-commercial use with the permission of the author/s and according to publisher conditions. For further rights please contact the publisher.

Keywords

  • Biomarkers
  • Colonoscopy
  • Crohn's Disease
  • Imaging
  • Monitoring
  • Recurrence
  • Ultrasound

Fingerprint

Dive into the research topics of 'Diagnostic accuracy of noninvasive biomarkers and imaging for evaluating postoperative recurrence in Crohn's disease'. Together they form a unique fingerprint.

Cite this