T1 - Effect of dosing cup size on the aerosol performance of high-dose carrier-based formulations in a novel dry powder inhaler
AU - Yeung, Stewart
AU - Traini, Daniela
AU - Tweedie, Alan
AU - Lewis, David
AU - Church, Tanya
AU - Young, Paul M.
PY - 2019/2
Y1 - 2019/2
N2 - This study investigated how varying the dosing cup size of a novel reservoir dry powder inhaler (DPI) affects the detachment of a micronized active pharmaceutical ingredient from larger carrier particles, and the aerosol performance of a DPI carrier formulation. Three different-sized dosing cups were designed: 3D printed with cup volumes of 16.26 mm3 , 55.99 mm3 , and 133.04 mm3 , and tested with five different carrier type formulations with beclomethasone dipropionate (BDP) concentrations between 1% and 30% (w/w). The morphology of the BDP attached to the carrier was investigated using scanning electron microscopy and the aerosol performance using the Next Generation Impactor. Increasing the volume of the dosing cup led to a reduction of BDP deposition in the Next Generation Impactor preseparator, and an increase in BDP detachment from the carrier was observed, leading to increased aerosol performance. The decreased amount of BDP attached to carrier after aerosolization was attributed to the increased dosing cup void volume. This may enable greater particle-particle and particle-wall collisions, with greater BDP detachment from the carrier and deagglomeration of smaller agglomerates. The dosing cup volume was observed to have significant influence on particle dispersion and the overall aerosol performance of a DPI.
AB - This study investigated how varying the dosing cup size of a novel reservoir dry powder inhaler (DPI) affects the detachment of a micronized active pharmaceutical ingredient from larger carrier particles, and the aerosol performance of a DPI carrier formulation. Three different-sized dosing cups were designed: 3D printed with cup volumes of 16.26 mm3 , 55.99 mm3 , and 133.04 mm3 , and tested with five different carrier type formulations with beclomethasone dipropionate (BDP) concentrations between 1% and 30% (w/w). The morphology of the BDP attached to the carrier was investigated using scanning electron microscopy and the aerosol performance using the Next Generation Impactor. Increasing the volume of the dosing cup led to a reduction of BDP deposition in the Next Generation Impactor preseparator, and an increase in BDP detachment from the carrier was observed, leading to increased aerosol performance. The decreased amount of BDP attached to carrier after aerosolization was attributed to the increased dosing cup void volume. This may enable greater particle-particle and particle-wall collisions, with greater BDP detachment from the carrier and deagglomeration of smaller agglomerates. The dosing cup volume was observed to have significant influence on particle dispersion and the overall aerosol performance of a DPI.
KW - aerosol performance
KW - carrier formulation
KW - dosing cup size
KW - impaction forces
KW - reservoir-based dry powder inhaler
UR - http://www.scopus.com/inward/record.url?scp=85056715650&partnerID=8YFLogxK
UR - http://purl.org/au-research/grants/arc/LP120200744
U2 - 10.1016/j.xphs.2018.09.033
DO - 10.1016/j.xphs.2018.09.033
M3 - Article
C2 - 30312722
AN - SCOPUS:85056715650
SN - 0022-3549
VL - 108
SP - 949
EP - 959
JO - Journal of Pharmaceutical Sciences
JF - Journal of Pharmaceutical Sciences