T1 - Effect of pupil size on multifocal pattern visual evoked potentials
AU - Martins, Alessandra
AU - Balachandran, Chandra
AU - Klistorner, Alexander I.
AU - Graham, Stuart L.
AU - Billson, Francis A.
PY - 2003/8
Y1 - 2003/8
N2 - The purpose of this study was to investigate the influence of pupil diameter on the amplitude and latency of multifocal visual evoked potentials (mfVEP). The multifocal objective perimeter (Accumap; Objectivision) was used to stimulate the visual field at 56 sites extending to 32° using a pseudorandom pattern stimulus. The mfVEP were recorded using bipolar occipital electrodes, 7 min/eye. Ten normal subjects were recruited from the community and one eye was randomly selected for testing. The mfVEP were recorded at four different pupil diameters (2 mm, 4 mm, 6 mm, 8 mm), obtained by applying tropicamide (0.5%) or pilocarpine (2%) in different dilutions. Appropriate refractive correction was provided to overcome cycloplegia and achieve a visual acuity of 6/7.5 or better. Analysis revealed that at most pupil diameters the normalized full field amplitude did not show significant variation, except at the most miotic pupil diameter (2 mm), where the amplitude became reduced, based on 2-way anova and Tukey's T method. There was, however, significant correlation between latency and pupil area (correlation coefficient: upper field -0.63, lower field -0.76). The results suggest that even in the presence of mydriatics or miotics, the mfVEP test can be used to assess diseases that affect amplitude, provided near correction is used. The interpretation of latency, however, must be made with caution, as a borderline conduction defect with a dilated pupil may appear normal.
AB - The purpose of this study was to investigate the influence of pupil diameter on the amplitude and latency of multifocal visual evoked potentials (mfVEP). The multifocal objective perimeter (Accumap; Objectivision) was used to stimulate the visual field at 56 sites extending to 32° using a pseudorandom pattern stimulus. The mfVEP were recorded using bipolar occipital electrodes, 7 min/eye. Ten normal subjects were recruited from the community and one eye was randomly selected for testing. The mfVEP were recorded at four different pupil diameters (2 mm, 4 mm, 6 mm, 8 mm), obtained by applying tropicamide (0.5%) or pilocarpine (2%) in different dilutions. Appropriate refractive correction was provided to overcome cycloplegia and achieve a visual acuity of 6/7.5 or better. Analysis revealed that at most pupil diameters the normalized full field amplitude did not show significant variation, except at the most miotic pupil diameter (2 mm), where the amplitude became reduced, based on 2-way anova and Tukey's T method. There was, however, significant correlation between latency and pupil area (correlation coefficient: upper field -0.63, lower field -0.76). The results suggest that even in the presence of mydriatics or miotics, the mfVEP test can be used to assess diseases that affect amplitude, provided near correction is used. The interpretation of latency, however, must be made with caution, as a borderline conduction defect with a dilated pupil may appear normal.
UR - http://www.scopus.com/inward/record.url?scp=0141522489&partnerID=8YFLogxK
U2 - 10.1046/j.1442-9071.2003.00669.x
DO - 10.1046/j.1442-9071.2003.00669.x
M3 - Article
C2 - 12880463
AN - SCOPUS:0141522489
SN - 1442-6404
VL - 31
SP - 354
EP - 356
JO - Clinical and Experimental Ophthalmology
JF - Clinical and Experimental Ophthalmology
IS - 4
ER -