TY - JOUR
T1 - Effects of temperature and composition on the viscosity of respiratory gases
AU - Turner, M. J.
AU - MacLeod, I. M.
AU - Rothberg, A. D.
PY - 1989
Y1 - 1989
N2 - The steady-state sensitivity of resistance pneumotachographs is proportional to viscosity. Dynamic characteristics of pneumotachographs, pressure transducers, and mass spectrometers are also viscosity dependent. We derive linear equations to approximate the viscosities of O2, N2, CO2, H2O, He, N2O, and Ar for temperatures between 20 and 40°C by using published viscosity data and a nonlinear extrapolation equation. We verify the accuracy of the extrapolation equation by comparison with published data. Our linear equations for pure gas viscosities yield standard errors <0.35 μP. We also compare a nonlinear equation for calculating the viscosities of mixtures of gases with published measured viscosities of dry air, humid air, and He-O2 and N2-CO2 mixtures. The maximum difference between published and calculated values is 1.3% for 10% CO2 in N2. All other differences are <0.38%. For saturated humid air at 35°C, a linear concentration-weighted combination of viscosities differs from our nonlinear equation by 4.9, 2.1, and 1.7% at barometric pressures of 32, 83, and 100 kPa, respectively. By use of our method, the viscosity of normal respiratory gases can be calculated to within 1% of measured values.
AB - The steady-state sensitivity of resistance pneumotachographs is proportional to viscosity. Dynamic characteristics of pneumotachographs, pressure transducers, and mass spectrometers are also viscosity dependent. We derive linear equations to approximate the viscosities of O2, N2, CO2, H2O, He, N2O, and Ar for temperatures between 20 and 40°C by using published viscosity data and a nonlinear extrapolation equation. We verify the accuracy of the extrapolation equation by comparison with published data. Our linear equations for pure gas viscosities yield standard errors <0.35 μP. We also compare a nonlinear equation for calculating the viscosities of mixtures of gases with published measured viscosities of dry air, humid air, and He-O2 and N2-CO2 mixtures. The maximum difference between published and calculated values is 1.3% for 10% CO2 in N2. All other differences are <0.38%. For saturated humid air at 35°C, a linear concentration-weighted combination of viscosities differs from our nonlinear equation by 4.9, 2.1, and 1.7% at barometric pressures of 32, 83, and 100 kPa, respectively. By use of our method, the viscosity of normal respiratory gases can be calculated to within 1% of measured values.
UR - http://www.scopus.com/inward/record.url?scp=0024319631&partnerID=8YFLogxK
M3 - Article
C2 - 2503494
AN - SCOPUS:0024319631
SN - 0161-7567
VL - 67
SP - 472
EP - 477
JO - Journal of Applied Physiology
JF - Journal of Applied Physiology
IS - 1
ER -