TY - JOUR
T1 - Estimation of cardiac stroke volume from radial pulse waveform by artificial neural network
AU - Xiao, Hanguang
AU - Liu, Daidai
AU - Avolio, Alberto P.
AU - Chen, Kai
AU - Li, Decai
AU - Hu, Bo
AU - Butlin, Mark
PY - 2022/5
Y1 - 2022/5
N2 - Background and Objectives: Stroke volume (SV) and cardiac output (CO) are the key indicators for the evaluation of cardiac function and hemodynamic status during the perioperative period, which are very important in the detection and treatment of cardiovascular diseases. Traditional CO and SV measurement methods have problems such as complex operation, low precision and poor generalization ability. Methods: In this paper, a method for estimating stroke volume based on cascade artificial neural network (ANN) and time domain features of radial pulse waveform (SVANN) was proposed. The simulation datasets of 4000 radial pulse waveforms and stroke volume (SVmeas) were generated by a 55 segment transmission line model of the human systemic vasculature and a recursive algorithm. The ANN was trained and tested by 10-fold cross-validation, and compared with 12 traditional models. Results: Experimental results showed that the Pearson correlation coefficients and mean difference between SVANN and SVmeas (R=0.95, mean standard deviation (SD) = 0.00 ± 6.45) were better than the best results of the 12 traditional models. Moreover, as increasing the number of training samples, the performance improvement of the ANN (R=0.94(Δ + 0.04), mean ± SD = 0.00 ± 6.38(Δ± 2.02)) was better than the other best model, namely, multiple linear regression model (MLR) (R=0.93(Δ + 0.03), mean ± SD = 0.00 ± 6.99(Δ± 1.50)). Conclusions: A method is proposed to estimate cardiac stroke volume by the ANN with time domain features of radial pulse wave. It avoids the complicated modeling process based on hemodynamics within traditional models, improves the estimation accuracy of SV, and has a good generalization ability.
AB - Background and Objectives: Stroke volume (SV) and cardiac output (CO) are the key indicators for the evaluation of cardiac function and hemodynamic status during the perioperative period, which are very important in the detection and treatment of cardiovascular diseases. Traditional CO and SV measurement methods have problems such as complex operation, low precision and poor generalization ability. Methods: In this paper, a method for estimating stroke volume based on cascade artificial neural network (ANN) and time domain features of radial pulse waveform (SVANN) was proposed. The simulation datasets of 4000 radial pulse waveforms and stroke volume (SVmeas) were generated by a 55 segment transmission line model of the human systemic vasculature and a recursive algorithm. The ANN was trained and tested by 10-fold cross-validation, and compared with 12 traditional models. Results: Experimental results showed that the Pearson correlation coefficients and mean difference between SVANN and SVmeas (R=0.95, mean standard deviation (SD) = 0.00 ± 6.45) were better than the best results of the 12 traditional models. Moreover, as increasing the number of training samples, the performance improvement of the ANN (R=0.94(Δ + 0.04), mean ± SD = 0.00 ± 6.38(Δ± 2.02)) was better than the other best model, namely, multiple linear regression model (MLR) (R=0.93(Δ + 0.03), mean ± SD = 0.00 ± 6.99(Δ± 1.50)). Conclusions: A method is proposed to estimate cardiac stroke volume by the ANN with time domain features of radial pulse wave. It avoids the complicated modeling process based on hemodynamics within traditional models, improves the estimation accuracy of SV, and has a good generalization ability.
KW - Cardiac stroke volume
KW - Artificial neural network
KW - Cardiac output
KW - Radial pulse waveform
UR - http://www.scopus.com/inward/record.url?scp=85126539184&partnerID=8YFLogxK
U2 - 10.1016/j.cmpb.2022.106738
DO - 10.1016/j.cmpb.2022.106738
M3 - Article
C2 - 35303487
SN - 0169-2607
VL - 218
SP - 1
EP - 9
JO - Computer Methods and Programs in Biomedicine
JF - Computer Methods and Programs in Biomedicine
M1 - 106738
ER -