T1 - Estimation of central aortic systolic pressure using late systolic inflection of radial artery pulse and its application to vasodilator therapy
AU - Takazawa, Kenji
AU - Kobayashi, Hiroshi
AU - Kojima, Iwao
AU - Aizawa, Akira
AU - Kinoh, Mineko
AU - Sugo, Yumi
AU - Shimizu, Masayuki
AU - Miyawaki, Yoshinori
AU - Tanaka, Nobuhiro
AU - Yamashina, Akira
AU - Avolio, Alberto
PY - 2012/5
Y1 - 2012/5
N2 - Background: Central blood pressure (BP) is a useful predictor of cardiovascular risk. Recently, a fully automated device that measures central SBP (cSBP) from radial late SBP (rSBP2) has been developed. Method: We measured cSBP using this device, compared it with aortic SBP (aSBP) measured with a high-fidelity pressure sensor, and evaluated the accuracy of cSBP before and after vasodilator administration. The data of 66 patients (mean age, 63.4 ± 9.7 years; 49 men) who underwent cardiac catheterization were analyzed. The radial artery pulse waveform and brachial BP were measured sequentially and used to calculate cSBP. Brachial SBP and DBP were used for radial SBP (rSBP) and radial DBP to calculate the absolute value of rSBP2. The radial pulse waveform was recorded by an applanation tonometer (HEM-9000AI; Omron Healthcare Co. Ltd). A high-fidelity pressure sensor was placed in the ascending aorta, and aSBP was measured simultaneously by an invasive method. Results: Significant positive correlations between directly measured aortic late SBP and cSBP or rSBP were observed (r = 0.93, 0.88, respectively). Changes in aSBP before and after vasodilator administration showed a trend toward higher correlation with changes in cSBP than with changes in rSBP (r = 0.84, 0.78, respectively). The slope of the linear regression line of aSBP with cSBP (slope: 0.94) was closer to unity than with rSBP (0.66). Conclusion: Noninvasive cSBP calculated with rSBP2 accorded well with aSBP measured by the invasive method. Vasodilator medication and four of five diseases did not affect this relation.
AB - Background: Central blood pressure (BP) is a useful predictor of cardiovascular risk. Recently, a fully automated device that measures central SBP (cSBP) from radial late SBP (rSBP2) has been developed. Method: We measured cSBP using this device, compared it with aortic SBP (aSBP) measured with a high-fidelity pressure sensor, and evaluated the accuracy of cSBP before and after vasodilator administration. The data of 66 patients (mean age, 63.4 ± 9.7 years; 49 men) who underwent cardiac catheterization were analyzed. The radial artery pulse waveform and brachial BP were measured sequentially and used to calculate cSBP. Brachial SBP and DBP were used for radial SBP (rSBP) and radial DBP to calculate the absolute value of rSBP2. The radial pulse waveform was recorded by an applanation tonometer (HEM-9000AI; Omron Healthcare Co. Ltd). A high-fidelity pressure sensor was placed in the ascending aorta, and aSBP was measured simultaneously by an invasive method. Results: Significant positive correlations between directly measured aortic late SBP and cSBP or rSBP were observed (r = 0.93, 0.88, respectively). Changes in aSBP before and after vasodilator administration showed a trend toward higher correlation with changes in cSBP than with changes in rSBP (r = 0.84, 0.78, respectively). The slope of the linear regression line of aSBP with cSBP (slope: 0.94) was closer to unity than with rSBP (0.66). Conclusion: Noninvasive cSBP calculated with rSBP2 accorded well with aSBP measured by the invasive method. Vasodilator medication and four of five diseases did not affect this relation.
UR - http://www.scopus.com/inward/record.url?scp=84859905759&partnerID=8YFLogxK
U2 - 10.1097/HJH.0b013e3283524910
DO - 10.1097/HJH.0b013e3283524910
M3 - Article
C2 - 22469836
AN - SCOPUS:84859905759
SN - 0263-6352
VL - 30
SP - 908
EP - 916
JO - Journal of Hypertension
JF - Journal of Hypertension
IS - 5
ER -