Evaluating carotid femoral pulse wave velocity measured by cuff-based approach against the tonometry-based reference standard in a paediatric population

Tommy Cai, Alice Meroni, Hasthi Dissanayake, Melinda Phang, Alberto Avolio, David Cellermajer, Mark Butlin, Michael Skilton, Ahmad Qasem

    Research output: Contribution to journalMeeting abstractpeer-review

    33 Downloads (Pure)

    Abstract

    Background: Carotid femoral pulse wave velocity (cfPWV) is directly associated with arterial stiffness in major elastic arteries and predicts future cardiovascular events (1). Little is known of cfPWV as a marker of vascular health in children. Semi-automated cuff-based devices for assessing cfPWV are increasingly popular, although these utilize an algorithm developed and validated in adults (2). Physiological differences between adults and children may thus reduce the accuracy of cuff-based.

    Methods: We sought to determine the accuracy of a cuff-based cfPWV device in healthy children and determine whether an age-appropriate algorithm increases accuracy. Methods we prospectively recruited 29 healthy children (mean age = 11.5 ± 5.2 years old). cfPWV was measured using a tonometer on the carotid artery and an inflated cuff on the thigh (Sphygmocor XCEL; AtCor Medical, Australia), and using a tonometer on both the carotid artery and femoral artery (SphygmoCor CvMS; AtCor Medical, Australia) as a reference method. We assessed the accuracy of the cuff-based device with its standard algorithm that was developed in adults, and an adjusted algorithm corrected for physiological differences in leg (femoral to thigh cuff) PWV between adult and children (3).

    Results: Cuff-based device estimates of cfPWV in children had excellent agreement to the reference standard (r = 0.85; Δ = −0.26 ms−1 [SD 0.44]). The adjusted algorithm improved the accuracy of the cuff-based method (r = 0.84; Δ=0.02 ms−1 [SD 0.44]) (Figure 1).

    Conclusions: Although the cuff-based semi-automatic approach estimates cfPWV with excellent agreement to the reference standard, adjusting the algorithm for known differences in leg PWV improves the accuracy of cuff-based measurement in children.
    Original languageEnglish
    Article numberP165
    Pages (from-to)128
    Number of pages1
    JournalArtery Research
    Volume24
    Issue numberC
    DOIs
    Publication statusPublished - 2018
    EventAssociation for Research into Arterial Structure and Physiology Conference 2019: ARTERY 2019 - Budapest, Hungary
    Duration: 10 Oct 201912 Oct 2019

    Bibliographical note

    Version archived for private and non-commercial use with the permission of the author/s and according to publisher conditions. For further rights please contact the publisher.

    Fingerprint

    Dive into the research topics of 'Evaluating carotid femoral pulse wave velocity measured by cuff-based approach against the tonometry-based reference standard in a paediatric population'. Together they form a unique fingerprint.

    Cite this