TY - JOUR
T1 - Hemodynamic effects of the anastomoses in the modified blalock-taussig shunt
T2 - a numerical study using a 0D/3D coupling method
AU - Zhao, Xi
AU - Liu, Youjun
AU - Ding, Jinli
AU - Ren, Xiaochen
AU - Bai, Fan
AU - Zhang, Mingzi
AU - Ma, Liancai
AU - Wang, Wenxin
AU - Xie, Jinsheng
AU - Qiao, Aike
PY - 2015/2/25
Y1 - 2015/2/25
N2 - The modified Blalock-Taussig (BT) shunt is a palliative surgery which can help the tetralogy of Fallot (TOF) patient increase the blood oxygen saturation by interposing a systemic-to-pulmonary artery shunt. Two typical anastomotic shapes are frequently used in clinical practice: the end-to-side (ETS) and the side-to-side (STS) anastomosis. This paper examines the hemodynamic influence of the anastomotic shape in the modified BT shunt. Three models with different anastomotic shapes were reconstructed. The ETS anastomoses were applied in the first model. For the innominate artery (IA) and the pulmonary artery (PA) in the second model, the ETS and the STS anastomosis were applied, respectively. Finally, the STS anastomoses were applied in the third model. The 0D/3D coupling method was used to perform a numerical simulation by coupling the three-dimensional (3D) artery model with a zero-dimensional (0D) lumped parameter model for the cardiovascular system. The simulation results showed that the perfusion into the left and right PA in Model 1 was unbalanced. Swirling flow appeared in the shunt in Model 3, but the shunt flow rate in Model 3 was lower. The ETS anastomosis at the PA may cause unbalanced blood perfusion into the left and right PA. Conversely, the STS anastomosis can make the blood perfusion more balanced. Otherwise, the STS anastomosis at the IA could generate a swirling flow in the shunt which may provide a better hemodynamic environment while decreasing the pulmonary perfusion.
AB - The modified Blalock-Taussig (BT) shunt is a palliative surgery which can help the tetralogy of Fallot (TOF) patient increase the blood oxygen saturation by interposing a systemic-to-pulmonary artery shunt. Two typical anastomotic shapes are frequently used in clinical practice: the end-to-side (ETS) and the side-to-side (STS) anastomosis. This paper examines the hemodynamic influence of the anastomotic shape in the modified BT shunt. Three models with different anastomotic shapes were reconstructed. The ETS anastomoses were applied in the first model. For the innominate artery (IA) and the pulmonary artery (PA) in the second model, the ETS and the STS anastomosis were applied, respectively. Finally, the STS anastomoses were applied in the third model. The 0D/3D coupling method was used to perform a numerical simulation by coupling the three-dimensional (3D) artery model with a zero-dimensional (0D) lumped parameter model for the cardiovascular system. The simulation results showed that the perfusion into the left and right PA in Model 1 was unbalanced. Swirling flow appeared in the shunt in Model 3, but the shunt flow rate in Model 3 was lower. The ETS anastomosis at the PA may cause unbalanced blood perfusion into the left and right PA. Conversely, the STS anastomosis can make the blood perfusion more balanced. Otherwise, the STS anastomosis at the IA could generate a swirling flow in the shunt which may provide a better hemodynamic environment while decreasing the pulmonary perfusion.
UR - http://www.scopus.com/inward/record.url?scp=84928473870&partnerID=8YFLogxK
U2 - 10.1142/S0219519415500177
DO - 10.1142/S0219519415500177
M3 - Article
AN - SCOPUS:84928473870
SN - 0219-5194
VL - 15
SP - 1
EP - 18
JO - Journal of Mechanics in Medicine and Biology
JF - Journal of Mechanics in Medicine and Biology
IS - 1
M1 - 1550017
ER -