Skip to main navigation Skip to search Skip to main content

New perspectives on non-invasive blood pressure measurement

Research output: Chapter in Book/Report/Conference proceeding › Conference proceeding contribution › peer-review

Abstract

Noninvasive blood pressure (NIBP) devices are calibrated against validated auscultation sphygmomanometers using Korotkoff sounds. This study aimed to investigate the timing of Korotkoff sounds in relation to pulse appearance in the brachial artery and values of intra-arterial blood pressure. Experiments were carried out on 15 participants, (14 males, 64.3 ± 10.4 years; one female, 86 yo), undergoing coronary angiography. A conventional occluding cuff, with a microphone for Korotkoff sounds, was placed on the upper arm (on the brachial artery). Intra-arterial blood pressure (IABP) was measured below the cuff with a fluid-filled catheter inserted via the radial artery and an external transducer. Finger photoplethysmography was used to measure brachial pulse wave velocity (PWV). Korotkoff sounds were processed electronically and custom algorithms identified the cuff pressure (CP) at which the first and last Korotkoff sounds were heard. PWV and max slope of the IABP pressure pulse were recorded to estimate arterial stiffness. The brachial artery closed at a CP of 132.0 ± 17.1 mmHg. Systolic and diastolic blood pressure (SBP and DBP) were 147.6 ± 14.3 and 72.7 ± 10.1 mmHg; mean pressure (MP, 100.1 ± 10.4 mmHg) was similar to MP derived from the peak of the oscillogram (98.5 ± 13.6 mmHg). Difference between IABP and CP recorded at first and last occurrence of Korotkoff sounds were, SBP: 19.0 ± 8.3 (range 2-29) mmHg, DBP: 4.0 ± 4.3 (range 2-12) mmHg. SBP derived from the onset of Korotkoff sounds can underestimate IABP by up to 19 mmHg. Since Korotkoff sounds are the recommended method mandated by the universal standard for the validation of blood pressure measuring devices, these errors are propagated through to all NIBP measurement devices irrespective of whether they use auscultatory or oscillometric methods.

Original languageEnglish
Title of host publication2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Conference (EMBC)
Place of PublicationUSA
PublisherInstitute of Electrical and Electronics Engineers (IEEE)
Number of pages4
ISBN (Electronic)9798350324471
ISBN (Print)9798350324488
DOIs
Publication statusPublished - 1 Jul 2023
EventAnnual International Conference of the IEEE Engineering in Medicine and Biology Conference (45th : 2023) - Sydney, Australia
Duration: 24 Jul 2023 → 27 Jul 2023

Publication series

NameAnnual International Conference of the IEEE Engineering in Medicine and Biology Society
PublisherInstitute of Electrical and Electronics Engineers (IEEE)
Volume2023
ISSN (Electronic)2694-0604

Conference

ConferenceAnnual International Conference of the IEEE Engineering in Medicine and Biology Conference (45th : 2023)
Abbreviated titleEMBC 2023
Country/TerritoryAustralia
CitySydney
Period24/07/23 → 27/07/23

Keywords

  • Male
  • Humans
  • Female
  • Blood Pressure/physiology
  • Pulse Wave Analysis
  • Blood Pressure Determination
  • Sphygmomanometers
  • Auscultation/methods

Fingerprint

Dive into the research topics of 'New perspectives on non-invasive blood pressure measurement'. Together they form a unique fingerprint.

Cite this