TY - JOUR
T1 - Normalization of visual evoked potentials using underlying electroencephalogram levels improves amplitude reproducibility in rats
AU - You, Yuyi
AU - Thie, Johnson
AU - Klistorner, Alexander
AU - Gupta, Vivek K.
AU - Graham, Stuart L.
PY - 2012/3
Y1 - 2012/3
N2 - PURPOSE. The visual evoked potential (VEP) is a frequently used noninvasive measurement of visual function. However, highamplitude variability has limited its potential for evaluating axonal damage in both laboratory and clinical research. This study was conducted to improve the reliability of VEP amplitude measurement in rats by using electroencephalogram (EEG)-based signal correction. METHODS. VEPs of Sprague-Dawley rats were recorded on three separate days within 2 weeks. The original VEP traces were normalized by EEG power spectrum, which was evaluated by Fourier transform. A comparison of intersession reproducibility and intersubject variability was made between the original and corrected signals. RESULTS. Corrected VEPs showed lower amplitude intersession within-subject SD (Sw), coefficient of variation (CoV), and repeatability (R 95) than the original signals (P < 0.001). The intraclass correlation coefficient (ICC) of the corrected traces (0.90) was also better than the original potentials (0.82). For intersubject variability, the EEG-based normalization improved the CoV from 44.64% to 30.26%. A linear correlation was observed between the EEG level and the VEP amplitude (r = 0.71, P < 0.0001). CONCLUSIONS. Underlying EEG signals should be considered in measuring the VEP amplitude. In this study, a useful technique was developed for VEP data processing that could also be used for other cortical evoked potential recordings and for clinical VEP interpretation in humans.
AB - PURPOSE. The visual evoked potential (VEP) is a frequently used noninvasive measurement of visual function. However, highamplitude variability has limited its potential for evaluating axonal damage in both laboratory and clinical research. This study was conducted to improve the reliability of VEP amplitude measurement in rats by using electroencephalogram (EEG)-based signal correction. METHODS. VEPs of Sprague-Dawley rats were recorded on three separate days within 2 weeks. The original VEP traces were normalized by EEG power spectrum, which was evaluated by Fourier transform. A comparison of intersession reproducibility and intersubject variability was made between the original and corrected signals. RESULTS. Corrected VEPs showed lower amplitude intersession within-subject SD (Sw), coefficient of variation (CoV), and repeatability (R 95) than the original signals (P < 0.001). The intraclass correlation coefficient (ICC) of the corrected traces (0.90) was also better than the original potentials (0.82). For intersubject variability, the EEG-based normalization improved the CoV from 44.64% to 30.26%. A linear correlation was observed between the EEG level and the VEP amplitude (r = 0.71, P < 0.0001). CONCLUSIONS. Underlying EEG signals should be considered in measuring the VEP amplitude. In this study, a useful technique was developed for VEP data processing that could also be used for other cortical evoked potential recordings and for clinical VEP interpretation in humans.
UR - http://www.scopus.com/inward/record.url?scp=84860545548&partnerID=8YFLogxK
U2 - 10.1167/iovs.11-8797
DO - 10.1167/iovs.11-8797
M3 - Article
C2 - 22297498
AN - SCOPUS:84860545548
SN - 0146-0404
VL - 53
SP - 1473
EP - 1478
JO - Investigative Ophthalmology and Visual Science
JF - Investigative Ophthalmology and Visual Science
IS - 3
ER -