TY - JOUR
T1 - Optimal preservation of the shark retina for ultrastructural analysis
T2 - an assessment of chemical, microwave, and high-pressure freezing fixation techniques
AU - Harahush, Blake K.
AU - Green, Kathryn
AU - Webb, Rick
AU - Hart, Nathan S.
AU - Collin, Shaun P.
PY - 2012/9
Y1 - 2012/9
N2 - Recent advances in microwave chemical fixation (MCF) and/or high pressure freezing (HPF) combined with transmission electron microscopy have resulted in superior ultrastructural detail in a variety of tissue types. To date, selachian tissue has been fixed and processed using only standard chemical fixation (CF) methods, and the resulting ultrastructure has been less than ideal. In this study, we compared the ultrastructure of the fragile retinal tissue from the brown banded bamboo shark, Chiloscyllium punctatum, obtained using CF, MCF, and HPF methods. For all fixation protocols, ultrastructural preservation was improved by keeping the tissue in oxygenated Ringer solution until the time of fixation. Both MCF and HPF produced superior retinal ultrastructure compared to conventional CF. Although HPF occasionally resulted in very high quality ultrastructure, microwave fixation was almost comparable, quicker and far more consistent.
AB - Recent advances in microwave chemical fixation (MCF) and/or high pressure freezing (HPF) combined with transmission electron microscopy have resulted in superior ultrastructural detail in a variety of tissue types. To date, selachian tissue has been fixed and processed using only standard chemical fixation (CF) methods, and the resulting ultrastructure has been less than ideal. In this study, we compared the ultrastructure of the fragile retinal tissue from the brown banded bamboo shark, Chiloscyllium punctatum, obtained using CF, MCF, and HPF methods. For all fixation protocols, ultrastructural preservation was improved by keeping the tissue in oxygenated Ringer solution until the time of fixation. Both MCF and HPF produced superior retinal ultrastructure compared to conventional CF. Although HPF occasionally resulted in very high quality ultrastructure, microwave fixation was almost comparable, quicker and far more consistent.
UR - http://www.scopus.com/inward/record.url?scp=84865420394&partnerID=8YFLogxK
UR - http://purl.org/au-research/grants/arc/DP0558844
U2 - 10.1002/jemt.22052
DO - 10.1002/jemt.22052
M3 - Article
C2 - 22581713
AN - SCOPUS:84865420394
SN - 1059-910X
VL - 75
SP - 1218
EP - 1228
JO - Microscopy Research and Technique
JF - Microscopy Research and Technique
IS - 9
ER -