Quantifying blood flow in the DIEP flap: an ultrasonographic study

Joseph Richard Dusseldorp, David G. Pennington

    Research output: Contribution to journalArticlepeer-review

    17 Citations (Scopus)
    37 Downloads (Pure)

    Abstract

    Background: The maximum weight of tissue that a single perforator can perfuse remains an important question in reconstructive microsurgery. An empirically based equation, known as the flap viability index (FVI), has been established to determine what weight of tissue will survive on one or more perforators. The equation is FVI = Sum d(n)^4/W, where d is the internal diameter of each perforator and W is the final weight of the flap. It has been shown that if FVI exceeds 10, total flap survival is likely, but if under 10, partial flap necrosis is probable. The aim of this study was to measure absolute flow rates in deep inferior epigastric perforator (DIEP) flap pedicles and assess correlation with the determinants of the FVI, perforator diameter and flap weight. Methods: Color Doppler ultrasound was used to quantify arterial flow in 10 consecutive DIEP flap pedicles 24 hours after anastomosis. In single-perforator DIEP flaps, flow rate was highly correlated with perforator diameter (r = 0.82, P = 0.01). Mean arterial flow rate was significantly reduced in DIEP flaps with 2 or more perforators (6 vs 38 cm³/min; P <0.05). Conclusions: This study confirms that perforator size is a critical factor in optimizing blood flow in perforator-based free tissue transfer. Further research is required to understand the flow dynamics of perforator flaps based on multiple perforators. However, surgeons should be cognizant that a single large perforator may have substantially higher flow rates than multiple small perforators. Routine FVI calculation is recommended to ensure complete flap survival.
    Original languageEnglish
    Article numbere228
    Pages (from-to)1-7
    Number of pages7
    JournalPlastic and reconstructive surgery. Global open
    Volume2
    Issue number10
    DOIs
    Publication statusPublished - 2014

    Bibliographical note

    Copyright the Author(s) 2014. Version archived for private and non-commercial use with the permission of the author/s and according to publisher conditions. For further rights please contact the publisher.

    Fingerprint

    Dive into the research topics of 'Quantifying blood flow in the DIEP flap: an ultrasonographic study'. Together they form a unique fingerprint.

    Cite this