Ray-tracing-guided myopic LASIK: real-world clinical outcomes

George He, Chandra Bala*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

16 Citations (Scopus)
10 Downloads (Pure)

Abstract

Purpose: To assess effectiveness of individualized ray-trace based laser in situ keratomileusis (LASIK) for correction of myopia in everyday clinical practice. Setting: Single-site private practice. Design: Retrospective nonrandomised unmasked chart review. Methods: Consecutive, myopic eyes (range ≤-8.25 diopters [D] sphere; astigmatism 0 to -4.25 D) treated with ray-trace based LASIK were included. Patients underwent wavefront, tomography, and biometry assessment using the InnovEyes Sightmap diagnostic device. The ray-trace based algorithm (InnovEyes algorithm) then generated an individualized 3D eye model and calculated a customized LASIK ablation profile. Postoperative visual acuity, refractive error and whole eye higher-order aberrations (HOAs) were evaluated over 3 months. Results: The procedure was performed on 400 eyes (200 patients). Mean preoperative manifest refraction spherical equivalent was -3.39 ± 1.58 D (right eye -3.84 ± 1.63 D, left eye -3.98 ± 1.75 D). At month 3, uncorrected distance visual acuity (UDVA) was ≥20/20 in all eyes, ≥20/16 in 89% (right eye 90%, left eye 89%), ≥20/12 in 51% (54% right eye; 47% left eye), and 20/10 in 8% (right eye 8%; left eye 9%) of eyes respectively. UDVA was within 1 line of preoperative corrected distance visual acuity in 98% of eyes (right eye 98.5%; left eye 98%) and 39% of eyes (right eye 38%; left eye 39%) gained 1 line improvement. There was a statistically but not clinically significant increase in total HOAs (right eye 0.06 ± 0.133 m; left eye 0.057 ± 0.125 m; P <.001). The spherical aberration decreased (right eye -0.047 ± 0.095 m, P <.001; left eye -0.051 ± 0.091 m, P <.001). Conclusions: Ray-trace based LASIK was safe and effective for correction of myopia with and without astigmatism. Approximately, half the eyes achieved ≥20/12.5 UDVA and 8% achieved 20/10. There was no clinically significant increase in total whole eye HOAs.

Original languageEnglish
Pages (from-to)1140-1146
Number of pages7
JournalJournal of Cataract and Refractive Surgery
Volume49
Issue number11
DOIs
Publication statusPublished - 1 Nov 2023
Externally publishedYes

Bibliographical note

Copyright the Author(s) 2023. Version archived for private and non-commercial use with the permission of the author/s and according to publisher conditions. For further rights please contact the publisher.

Fingerprint

Dive into the research topics of 'Ray-tracing-guided myopic LASIK: real-world clinical outcomes'. Together they form a unique fingerprint.

Cite this