Rest and treadmill exercise first-pass radionuclide ventriculography: Validation of left ventricular ejection fraction measurements

John D. Friedman, Daniel S. Berman*, Hosen Kiat, James Bietendorf, Mark Hyun, Kenneth F. Van Train, Fan Ping Wang

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

29 Citations (Scopus)

Abstract

Background: To assess the accuracy of rest and treadmill exercise first-pass radionuclide ventriculographic measurements of left ventricular ejection fraction (LVEF), 40 patients underwent treadmill exercise first-pass and bicycle exercise equilibrium radionuclide ventriculography. To determine the frequency of technically adequate treadmill exercise first-pass studies, an additional 128 consecutive patients undergoing treadmill exercise first-pass procedures during stress99mTc-labeled sestamibi myocardial perfusion studies were assessed. Methods and Results: The treadmill exercise first-pass procedure used a multicrystal camera and an241Am point source to allow for correction of patient motion. Excellent correlations were observed between resting first-pass and resting equilibrium LVEF (r=0.91; standard error of the estimate=5.6). A high correlation was also observed between treadmill exercise first-pass and bicycle equilibrium exercise LVEF measurements (r=0.85, standard error of the estimate=7.6). Treadmill first-pass LVEF systematically underestimated the bicycle equilibrium LVEF. Intraobserver agreement for rest and exercise first-pass LVEF was high (r values of 0.98 and 0.94, respectively). Of the 168 consecutive treadmill exercise first-pass studies evaluated for technical adequacy, 21 (12.5%) were deemed technically inadequate, with most of the sources of error being avoidable. The frequency of technically adequate studies was as high (87%) in high levels of exercise (Bruce stages 3 and 4) as in lower levels (88%). The findings of this study validate the first-pass treadmill exercise LVEF measurement. Conclusion: This procedure now provides the option for combining the information of peak treadmill exercise LVEF with measurements of exercise myocardial perfusion from the same injection of radioactivity.

Original languageEnglish
Pages (from-to)382-388
Number of pages7
JournalJournal of Nuclear Cardiology
Volume1
Issue number4
DOIs
Publication statusPublished - Jul 1994
Externally publishedYes

Keywords

  • first-pass radionuclide ventriculography
  • left ventricular ejection fraction
  • myocardial function
  • myocardial perfusion
  • Technetium 99m-labeled sestamibi

Fingerprint

Dive into the research topics of 'Rest and treadmill exercise first-pass radionuclide ventriculography: Validation of left ventricular ejection fraction measurements'. Together they form a unique fingerprint.

Cite this