TY - JOUR
T1 - Safety of osseointegrated implants for transfemoral amputees
T2 - A two-center prospective cohort study
AU - Muderis, Munjed Al
AU - Khemka, Aditya
AU - Lord, Sarah J.
AU - Van De Meent, Henk
AU - Frolke, Jan Paul M
PY - 2016/6/1
Y1 - 2016/6/1
N2 - Background: Osseointegrated implants are an alternative for prosthetic attachment for individuals unable to wear a socket following an amputation. The concept of an integrated metal implant communicating with the external environment raises substantial concern about the risk of ascending infection. We report on the safety of press-fit osseointegrated implants currently used in Australia and the Netherlands. Methods: We prospectively recorded all adverse events in all patients with transfemoral amputation who were managed with an osseointegration implant system between 2009 and 2013 at two centers. The procedure was performed in two stages. A customized porous-coated implant was placed in the first stage, and a stoma was created in the second. Adverse events were categorized according to type (infection or "other") and severity. Infections were classified according to four grades of severity based on clinical and radiographic findings: (1) low-grade soft-tissue infection, (2) high-grade softtissue infection, (3) bone infection, and (4) septic implant failure. Results: Eighty-six patients (ninety-one implants), twenty-five to eighty-one years of age, were included in the study and followed for a median of thirty-four months (range, twenty-four to seventy-one months). Thirty-one patients had an uneventful course with no complications; twenty-nine developed infection (all grade 1 or 2); and twenty-six did not develop infection but had one or more other complications requiring intervention, including stoma hypergranulation (seventeen patients), soft-tissue redundancy (fourteen), proximal femoral fracture (three), inadequate osseointegration leading to implant replacement (one), implant breakage (two), and breakage of the pin used as a fail-safe mechanism (twenty-five). Conclusions: Mild infection and irritation of the soft tissue in the skin-penetration area are common in transfemoral amputees who have an osseointegrated implant. These complications were successfully managed with simple measures. Severe infections resulting in septic implant loosening are rare.
AB - Background: Osseointegrated implants are an alternative for prosthetic attachment for individuals unable to wear a socket following an amputation. The concept of an integrated metal implant communicating with the external environment raises substantial concern about the risk of ascending infection. We report on the safety of press-fit osseointegrated implants currently used in Australia and the Netherlands. Methods: We prospectively recorded all adverse events in all patients with transfemoral amputation who were managed with an osseointegration implant system between 2009 and 2013 at two centers. The procedure was performed in two stages. A customized porous-coated implant was placed in the first stage, and a stoma was created in the second. Adverse events were categorized according to type (infection or "other") and severity. Infections were classified according to four grades of severity based on clinical and radiographic findings: (1) low-grade soft-tissue infection, (2) high-grade softtissue infection, (3) bone infection, and (4) septic implant failure. Results: Eighty-six patients (ninety-one implants), twenty-five to eighty-one years of age, were included in the study and followed for a median of thirty-four months (range, twenty-four to seventy-one months). Thirty-one patients had an uneventful course with no complications; twenty-nine developed infection (all grade 1 or 2); and twenty-six did not develop infection but had one or more other complications requiring intervention, including stoma hypergranulation (seventeen patients), soft-tissue redundancy (fourteen), proximal femoral fracture (three), inadequate osseointegration leading to implant replacement (one), implant breakage (two), and breakage of the pin used as a fail-safe mechanism (twenty-five). Conclusions: Mild infection and irritation of the soft tissue in the skin-penetration area are common in transfemoral amputees who have an osseointegrated implant. These complications were successfully managed with simple measures. Severe infections resulting in septic implant loosening are rare.
UR - http://www.scopus.com/inward/record.url?scp=84978858010&partnerID=8YFLogxK
U2 - 10.2106/JBJS.15.00808
DO - 10.2106/JBJS.15.00808
M3 - Article
C2 - 27252434
AN - SCOPUS:84978858010
VL - 98
SP - 900
EP - 909
JO - Journal of Bone and Joint Surgery - Series A
JF - Journal of Bone and Joint Surgery - Series A
SN - 0021-9355
IS - 11
ER -