TY - JOUR
T1 - Seeing electrode movement in the cochlea
T2 - Micro-focus fluoroscopy - A great tool for electrode development
AU - Xu, Jin
AU - Briggs, Rob
AU - Tyconcinski, Michael
AU - Newbold, Carrie
AU - Risi, Frank
AU - Cowan, Robert
PY - 2009
Y1 - 2009
N2 - The aim of this study was to utilise micro-focus X-ray fluoroscopy for viewing electrode movement in the cochlea. Various prototypes of newly designed cochlear implant electrodes were evaluated during insertion studies on human cadaver temporal bones. The magnified fluoroscopic images were observed in real-time and recorded for retrospective studies. In 30 insertions of hearing preservation (Hybrid-L) arrays, fluoroscopy provided crucial information on the tip design, length of array and stiffening stylet. In 44 insertions of Contour Advance enhanced (CAe) arrays, the length, curvature, depth of insertion and degree of stiffness were assessed. CAe arrays were successfully inserted to the designated depth and positioned close to the modiolus. High quality microfocus fluoroscopic images of electrode movement in the cochlea greatly assisted in the validation of newly designed intra-cochlear electrode arrays.
AB - The aim of this study was to utilise micro-focus X-ray fluoroscopy for viewing electrode movement in the cochlea. Various prototypes of newly designed cochlear implant electrodes were evaluated during insertion studies on human cadaver temporal bones. The magnified fluoroscopic images were observed in real-time and recorded for retrospective studies. In 30 insertions of hearing preservation (Hybrid-L) arrays, fluoroscopy provided crucial information on the tip design, length of array and stiffening stylet. In 44 insertions of Contour Advance enhanced (CAe) arrays, the length, curvature, depth of insertion and degree of stiffness were assessed. CAe arrays were successfully inserted to the designated depth and positioned close to the modiolus. High quality microfocus fluoroscopic images of electrode movement in the cochlea greatly assisted in the validation of newly designed intra-cochlear electrode arrays.
KW - Cochlea
KW - Electrode
KW - Insertion
KW - Micro-focus X-ray imaging
KW - Temporal bone
UR - http://www.scopus.com/inward/record.url?scp=65549094245&partnerID=8YFLogxK
U2 - 10.1002/cii.404
DO - 10.1002/cii.404
M3 - Article
C2 - 19142879
AN - SCOPUS:65549094245
VL - 10
SP - 115
EP - 119
JO - Cochlear implants international
JF - Cochlear implants international
SN - 1467-0100
IS - SUPPL. 1
ER -