Sources of error in partial rebreathing pulmonary blood flow measurements in lungs with emphysema and pulmonary embolism

J. S. Yem, M. J. Turner*, A. B. Baker

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

Background. Studies of the accuracy of partial rebreathing measurements of pulmonary blood flow (PBF) in patients with abnormal lungs have not fully explained the sources of error. Methods. We used computer models of emphysema and pulmonary embolism incorporating both ventilation-perfusion (V̇/Q) and ventilation-volume (V̇V) heterogeneity to investigate systematic errors in partial rebreathing PBF measurements. We studied (i) errors produced under usual conditions, (ii) effects of recirculation, (iii) effects of alveolar-proximal airway and alveolar-capillary Pco2 and V̇CO2 differences, (iv) effects of alveolar V̇/Q̇ inhomogeneity and (v) effects of rebreathing time. Results. In the pulmonary embolism model the systematic error is only acceptable (<10%) when the simulated PBF is low (2-3 litre min-1). In the emphysema model PBF is underestimated by more than 20% at all cardiac outputs studied. Four sources of systematic errors were found. (i) Alveolar-proximal airway Pco2 gradients and flux differences between the proximal airway and alveolar compartments contribute most to the systematic error. (ii) V̇/Q̇ inhomogeneity causes Pco2 gradients between the alveolar compartments and pulmonary capillary blood, and between pulmonary capillary compartments. (iii) Rebreathing times are inadequate in the presence of V̇/V mismatch. (iv) The apparent effect of venous blood recirculation is small in emphysema but significant in pulmonary embolism. Conclusions. We conclude that PBF cannot be measured accurately by partial rebreathing in lungs with emphysema or embolism. Systematic errors are caused mainly by errors in end-tidal Pco2 values.

Original languageEnglish
Pages (from-to)732-741
Number of pages10
JournalBritish Journal of Anaesthesia
Volume97
Issue number5
DOIs
Publication statusPublished - Nov 2006
Externally publishedYes

Keywords

  • Complications, error
  • Heart, cardiac output
  • Lung, disease
  • Lung, rebreathing

Fingerprint

Dive into the research topics of 'Sources of error in partial rebreathing pulmonary blood flow measurements in lungs with emphysema and pulmonary embolism'. Together they form a unique fingerprint.

Cite this