TY - JOUR
T1 - The reliability of crown-root ratio, linear and angular measurements on panoramic radiographs
AU - Stramotas, Steve
AU - Geenty, Joseph P.
AU - Darendeliler, M. Ali
AU - Byloff, Fritz
AU - Berger, Jeff
AU - Petocz, Peter
PY - 2000
Y1 - 2000
N2 - The aim of this study was to evaluate the reliability of crown and root length, crown-root ratio and angular measurements of teeth relative to constructed reference lines and to other teeth in the same region on consecutive (T1 and T2) panoramic radiographs (OPGs). This retrospective study employed 20 cases; ten with five implants in each jaw (age range between 20 and 60 years) and ten with a full permanent dentition (age range between 12 and 16 years). The consecutive pairs of OPGs ranged from 6 months to 3 years apart. Four variables were measured and compared: 1) the crown or coronal segment length and the root or apical segment length, 2) the crown-root ratio, 3) the angulations of teeth and implants relative to specific reference lines in each jaw, 4) the angle between teeth and implants in the same sextant. The results revealed that comparisons of measurements taken of the same structures at T1 and T2, there were no statistically significant differences (p>0.05) between vertical linear measurements. The crown-root ratios and coronal-apical segment ratios too, showed no significant differences (p>0.05). Whereas, angulations of teeth or implants relative to respective reference lines showed significant differences (p=0.001) for some of the teeth. These differences, however, were less than 5deg; a clinically acceptable range. Angles measured between teeth or implants in the same sextant showed no significant differences (p>0.05). These results seem to support the hypothesis, therefore, that the linear vertical measurements, ratio calculations and angular measurements can be used to compare crown and root lengths, crown-root ratios and tooth angulations on OPGs taken of the same patient at different times with consistent accuracy.
AB - The aim of this study was to evaluate the reliability of crown and root length, crown-root ratio and angular measurements of teeth relative to constructed reference lines and to other teeth in the same region on consecutive (T1 and T2) panoramic radiographs (OPGs). This retrospective study employed 20 cases; ten with five implants in each jaw (age range between 20 and 60 years) and ten with a full permanent dentition (age range between 12 and 16 years). The consecutive pairs of OPGs ranged from 6 months to 3 years apart. Four variables were measured and compared: 1) the crown or coronal segment length and the root or apical segment length, 2) the crown-root ratio, 3) the angulations of teeth and implants relative to specific reference lines in each jaw, 4) the angle between teeth and implants in the same sextant. The results revealed that comparisons of measurements taken of the same structures at T1 and T2, there were no statistically significant differences (p>0.05) between vertical linear measurements. The crown-root ratios and coronal-apical segment ratios too, showed no significant differences (p>0.05). Whereas, angulations of teeth or implants relative to respective reference lines showed significant differences (p=0.001) for some of the teeth. These differences, however, were less than 5deg; a clinically acceptable range. Angles measured between teeth or implants in the same sextant showed no significant differences (p>0.05). These results seem to support the hypothesis, therefore, that the linear vertical measurements, ratio calculations and angular measurements can be used to compare crown and root lengths, crown-root ratios and tooth angulations on OPGs taken of the same patient at different times with consistent accuracy.
KW - Accuracy
KW - Linear and angular measurements
KW - Panoramic radiographs
UR - http://www.scopus.com/inward/record.url?scp=0041947453&partnerID=8YFLogxK
U2 - 10.1034/j.1600-0544.2000.030404.x
DO - 10.1034/j.1600-0544.2000.030404.x
M3 - Article
C2 - 11553073
AN - SCOPUS:0041947453
SN - 1601-6335
VL - 3
SP - 182
EP - 191
JO - Orthodontics and Craniofacial Research
JF - Orthodontics and Craniofacial Research
IS - 4
ER -