TY - JOUR
T1 - The Vega advanced third generation posterior stabilized total knee arthroplasty system enables the restoration of range of motion for high demanding daily activities
T2 - a 5-years follow-up study
AU - Gerdesmeyer, Ludger
AU - Glowalla, Claudio
AU - Lasic, Igor
AU - Al Muderis, Munjed
AU - Weuster, Matthias
AU - Klueter, Tim
N1 - Copyright the Author(s) 2024. Version archived for private and non-commercial use with the permission of the author/s and according to publisher conditions. For further rights please contact the publisher.
PY - 2024/5/13
Y1 - 2024/5/13
N2 - Background The Vega System® PS (Aesculap AG, Tuttlingen, Germany) is an advanced, third generation fixed implant that aims to mimic natural knee kinematics by optimizing pivotal motion while reducing surface stress. This study evaluated mid-term survival and clinical outcomes, including range of motion (ROM) of the modern posterior stabilized implant in order to analyse whether this biomechanically successful implant reaches good results in situ. Methods The first 100 patients to receive the Vega PS System for total knee arthroplasty were invited to take part in this single centre, single surgeon study. Of these, 84 patients were clinically assessed 5-6 years postoperatively. Data which was obtained during this follow-up examination included revision data, range of motion and clinical scores. Results The 5-year survival rate for exchange of any component was 97.6%, whereby two patients required replacement of the polyethylene gliding surface. Secondary patella resurfacing was performed in 7 patients. Significantly improved results in comparison to the preoperative state could be obtained at the follow-up: KOOS improved from 39.4 to 78.8, SF-12 PCS improved from 32.1 to 42 SF-12 MCS improved from 46 to 53.8 and patella pain improved from 2.7 to 0.3. The mean ROM of the 84 patients after 5 years was 133.1 and mean total KSS was 189.9. Discussion & conclusions This study demonstrates a high survival rate of the Vega PS System® and significant improvements in clinical outcomes 5 years after implantation. The obtained mean ROM indicates that this implant provides good flexibility of the knee joint, allowing a high number of activities. However, due to the rate of secondary patella implantation, routine resurfacing of the patella for all PS TKA cases is highly recommended.
AB - Background The Vega System® PS (Aesculap AG, Tuttlingen, Germany) is an advanced, third generation fixed implant that aims to mimic natural knee kinematics by optimizing pivotal motion while reducing surface stress. This study evaluated mid-term survival and clinical outcomes, including range of motion (ROM) of the modern posterior stabilized implant in order to analyse whether this biomechanically successful implant reaches good results in situ. Methods The first 100 patients to receive the Vega PS System for total knee arthroplasty were invited to take part in this single centre, single surgeon study. Of these, 84 patients were clinically assessed 5-6 years postoperatively. Data which was obtained during this follow-up examination included revision data, range of motion and clinical scores. Results The 5-year survival rate for exchange of any component was 97.6%, whereby two patients required replacement of the polyethylene gliding surface. Secondary patella resurfacing was performed in 7 patients. Significantly improved results in comparison to the preoperative state could be obtained at the follow-up: KOOS improved from 39.4 to 78.8, SF-12 PCS improved from 32.1 to 42 SF-12 MCS improved from 46 to 53.8 and patella pain improved from 2.7 to 0.3. The mean ROM of the 84 patients after 5 years was 133.1 and mean total KSS was 189.9. Discussion & conclusions This study demonstrates a high survival rate of the Vega PS System® and significant improvements in clinical outcomes 5 years after implantation. The obtained mean ROM indicates that this implant provides good flexibility of the knee joint, allowing a high number of activities. However, due to the rate of secondary patella implantation, routine resurfacing of the patella for all PS TKA cases is highly recommended.
UR - http://www.scopus.com/inward/record.url?scp=85192865823&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0302885
DO - 10.1371/journal.pone.0302885
M3 - Article
C2 - 38739584
AN - SCOPUS:85192865823
SN - 1932-6203
VL - 19
SP - 1
EP - 13
JO - PLoS ONE
JF - PLoS ONE
IS - 5 May
M1 - e0302885
ER -