T1 - Utilization and outcomes of temporary mechanical circulatory support for graft dysfunction after heart transplantation
AU - Phan, Kevin
AU - Luc, Jessica G.Y.
AU - Xu, Joshua
AU - Maltais, Simon
AU - Stulak, John M.
AU - Yan, Tristan D.
AU - Tchantchaleishvili, Vakhtang
PY - 2017/1/1
Y1 - 2017/1/1
N2 - Graft dysfunction is the main cause of early mortality after heart transplantation. In cases of severe graft dysfunction, temporary mechanical circulatory support (TMCS) may be necessary. The aim of this systematic review was to examine the utilization and outcomes of TMCS in patients with graft dysfunction after heart transplantation. Electronic search was performed to identify all studies in the English literature assessing the use of TMCS for graft dysfunction. All identified articles were systematically assessed for inclusion and exclusion criteria. Of the 5,462 studies identified, 41 studies were included. Among the 11,555 patients undergoing heart transplantation, 695 (6.0%) required TMCS with patients most often supported using venoarterial extracorporeal membrane oxygenation (79.4%) followed by right ventricular assist devices (11.1%), biventricular assist devices (BiVADs) (7.5%), and left ventricular assist devices (LVADs) (2.0%). Patients supported by LVADs were more likely to be supported longer (p = 0.003), have a higher death by cardiac event (p = 0.013) and retransplantation rate (p = 0.015). In contrast, patients supported with BiVAD and LVAD were more likely to be weaned off support (p = 0.020). Overall, no significant difference was found in pooled 30 day survival (p = 0.31), survival to discharge (p = 0.19), and overall survival (p = 0.51) between the subgroups. Temporary mechanical circulatory support is an effective modality to support patients with graft dysfunction after heart transplantation. Further studies are needed to establish the optimal threshold and strategy for TMCS and to augment cardiac recovery and long-term survival.
AB - Graft dysfunction is the main cause of early mortality after heart transplantation. In cases of severe graft dysfunction, temporary mechanical circulatory support (TMCS) may be necessary. The aim of this systematic review was to examine the utilization and outcomes of TMCS in patients with graft dysfunction after heart transplantation. Electronic search was performed to identify all studies in the English literature assessing the use of TMCS for graft dysfunction. All identified articles were systematically assessed for inclusion and exclusion criteria. Of the 5,462 studies identified, 41 studies were included. Among the 11,555 patients undergoing heart transplantation, 695 (6.0%) required TMCS with patients most often supported using venoarterial extracorporeal membrane oxygenation (79.4%) followed by right ventricular assist devices (11.1%), biventricular assist devices (BiVADs) (7.5%), and left ventricular assist devices (LVADs) (2.0%). Patients supported by LVADs were more likely to be supported longer (p = 0.003), have a higher death by cardiac event (p = 0.013) and retransplantation rate (p = 0.015). In contrast, patients supported with BiVAD and LVAD were more likely to be weaned off support (p = 0.020). Overall, no significant difference was found in pooled 30 day survival (p = 0.31), survival to discharge (p = 0.19), and overall survival (p = 0.51) between the subgroups. Temporary mechanical circulatory support is an effective modality to support patients with graft dysfunction after heart transplantation. Further studies are needed to establish the optimal threshold and strategy for TMCS and to augment cardiac recovery and long-term survival.
KW - Graft failure
KW - Heart transplantation
KW - Temporary mechanical circulatory support
UR - http://www.scopus.com/inward/record.url?scp=85041325135&partnerID=8YFLogxK
U2 - 10.1097/MAT.0000000000000599
DO - 10.1097/MAT.0000000000000599
M3 - Review article
C2 - 28906273
AN - SCOPUS:85041325135
SN - 1058-2916
VL - 63
SP - 695
EP - 703
JO - ASAIO Journal
JF - ASAIO Journal
IS - 6
ER -